- measured boiler efficiency
- ≈73%
- rated efficiency
- 80%
- condensate recovered
- ≈4%
- boiler capacity
- 313 kg/h
The challenge
As part of a decarbonisation programme, the factory suspected that its 313 kg/hr gas-fired boiler was running below its rated performance, but had no measurements to confirm it or to size the fix.
Our approach
In May 2025 our team ran a one-hour loading test on the boiler and analysed the flue gas to calculate efficiency by the indirect method. We imaged the steam distribution lines with a FLIR thermal camera to find uninsulated sections and leaks, and surveyed how much condensate was returned to the boiler house. The work followed SREDA guidelines for boiler assessment.
The result
Boiler efficiency measured about 73% against 80% rated, with combustion efficiency of about 74%. Only about 4% of condensate was being recovered. The recommended measures, covering combustion tuning, insulation and condensate return, would bring the plant back to about 80%.
Why it matters
Every point of boiler efficiency lost is gas burned for nothing, every hour the boiler runs. Condensate that goes to drain takes its heat with it, and the fresh water that replaces it has to be treated and heated again from cold. On a boiler that runs all year, small losses add up to a large share of the gas bill.
What we recommended
- Tune combustion to bring excess air back to the right level, the lowest-cost measure
- Insulate the valves, flanges and fittings that the thermal images showed radiating heat
- Return condensate to the feed tank to recover its heat and its treated water
Together, these measures would bring the plant back to about 80% efficiency.